Creating Task for USB-6008 using LabWindows CVI

I want to use NI USB-6008 with Lab Windows CVI. I have NI DAQmx 7.5 installed on my PC.
Using LabView I could access USB-6008 and could do data acquisition.
 
But I could not create Task for USB-6008 in LabWindows. In Lab Windows the equipment is not
getting identified. It is giving as no Physical equipment is connected.
 
Do you I need do anything more to work with USB-6008 from LabWindows?
 
Thanks
Ravisankar
 
 
0 Kudos
Message 1 of 4
(3,658 Views)

Hi,

I have the same behaviour here with a USB-6009 😞

However using another approach i did get some data back from ADC namely using a driver called Ni DAQ Base MX which are also installed in the NI DAQ installation.

Using the sample programs i managed to get data from the device, but it should also be possible using the DAQ library functions, did you suceed later ?

If so i would like to know how ?

B.Rgds.

Peter PBI

Denmark

0 Kudos
Message 2 of 4
(3,640 Views)
Hi
 
I could create task for USB-6008 from labwindows after switching to new driver.
 
The link below gave me hint for this. You can also try this.
 
 
Ravi
HYDERABAD
INDIA
0 Kudos
Message 3 of 4
(3,635 Views)

Hi again,

Thank you very much Smiley Very Happy

Just tried switching driver and now there are more life, i will exmaine this more next week.

Have a nice weekend ;o)

Peter

PBI-Dansensor A/S

0 Kudos
Message 4 of 4
(3,631 Views)