How do I embedd user interfaces (UIR files)with the executable using CVI 5.0

I am currently distributing my application with seperate UIR files for each user interface. I need to embedd the UIR files and distribute just one file. How can i do that using Labwindows CVI 5.0 version
0 Kudos
Message 1 of 2
(2,916 Views)
That was a feature that was added in CVI 5.5 and above. You would need to upgrade to get that functionality. You can upgrade to the latest version of CVI (version 6.0) here.

Best Regards,

Chris Matthews