LabWindows/CVI

cancel
Showing results for 
Search instead for 
Did you mean: 

Multiple build actions not working

I did a quick look and coulding find this answered anywhere....
 
If I add two "post build" steps (just two lines of file-copy's), my build fails (CVI 8.0).  The batch file that CVI creates puts a CR, but no LF, between the two lines that were added in the text box, causing the command interpreter to try to run it as a single command.  I can get around it for now by creating an external batch fall and calling it from the CVI post-build-actions, but I thought I'd mention it so maybe it would get fixed in the next release.
0 Kudos
Message 1 of 2
(3,044 Views)
Thanks for the heads up. I've reproduced it and filed a bug report for this.



Bilal Durrani
NI
0 Kudos
Message 2 of 2
(2,999 Views)