03-14-2011 11:32 AM
These two modes on the strip chart control stopped working in my software with the 2010 upgrade. Continuous mode still works. I even loaded the NI example 'autoscaling.cws' that uses a strip chart control and modified it to default to sweep mode instead of continuous...it doesn't work either.
Any ideas?
Solved! Go to Solution.
03-14-2011 01:18 PM
Hello -
This is actually a known issue in CVI 2010 (ID 258827). I will be making a more official announcement regarding this issue on this forum soon. In the meantime, you can download and install the CVI 2010 Run-Time engine found here, which contains the fix.
Let me know if you have any questions -
NickB
National Instruments
03-14-2011 02:34 PM
Thanks! Works great now.