02-01-2007 11:45 AM
02-05-2007 11:08 PM
02-07-2007 07:41 PM
when I use "/?*INSTR" in viFindRsrc, it shows ASL1..., when I use "/FIREWIRE?*INSTR",
it gives :
NoN-Fatal run-time error, funtion viFindRsrc: (return value==-1073807343(0xbfff0011))
insufficient location information or the requested device or resource is not present in the system.
but my sony dfw x700 is connected, and max can see it.
02-09-2007 11:40 AM
zy9,
It looks like you are trying to do some sort of low level access to the camera. Do you have our NI-IMAQ 1394 driver? If not then you may need to do low-level access, but if so then you can use our sample programs, I would suggest looking in this folder: C:\Program Files\National Instruments\CVI80\samples\imaq1394\Samples without IMAQ Vision (the path may vary based on the name of your main drive and your version of CVI). They show the best ways to access and communicate with 1394 cameras through our software. Let me know if that helps and if you have any questions.
-Allison S.