Sorry I now this SUbject has been treated several times but i didn't get my x-scale fixed.
I wirded some the min and max values of y and x-scale to the property node.
the y axis now works and is alway in the same range.
the x scale instead never starts at 0 although i wired a 0 to the x.min.value of the property node.
where is the problem?
thx
Simon
 
PS: I unchecked the autoscale-property
Using Labview 7.1
0 Kudos
Message 1 of 3
(3,119 Views)
Hi, I'm afraid you posted this question to the wrong forum: you should post it to the LabVIEW one Smiley Wink


Proud to use LW/CVI from 3.1 on.

My contributions to the Developer Community
________________________________________
If I have helped you, why not giving me a kudos?
0 Kudos
Message 2 of 3
(3,112 Views)
Hello Simon,
I have tryed myself with LabVIEW 7.1 and it works correctly.
Can you post your VI here?
Then I have a look and can perhaps answer your question.