07-29-2014 03:19 AM
I tried to use the command SetAxisScalingMode in order to allow the user to see the histogram +0.1 after the maximum, and -0.1 below minimum:
SetAxisScalingMode (graphTabPanelHandle, TABPANEL_3_CCH, VAL_BOTTOM_XAXIS, VAL_MANUAL, -range-0.1, range+0.1);
However, instead of getting 0.0, I've got weird values like -5.6E-17 instead (please see the attached picture)
How can prevent that and solve this problem by always show more clear values with 0.1 intervals?
Solved! Go to Solution.
07-29-2014 03:40 AM
you're not alone... it has been reported earlier, see, for example, here
07-29-2014 03:50 AM
Thank you for your replay! I thought I did something wrong, I hope they would solve this problem as quickly as possible 🙂
07-29-2014
03:52 AM
- last edited on
11-18-2024
02:51 PM
by
Content Cleaner
Hello RaVen88,
Are you using LabWindows/CVI 2013?
The issue that Wolfgang pointed is fixed in 2013 Patch 1. The bug ID is 422256. You can see here details about LabWindows/CVI 2013 Patch 1.
If you upgrade to CVI 2013 Patch 1, or better CVI 2013 SP1 you shouldn't see the problem anymore.
Constantin
07-29-2014
04:00 AM
- last edited on
11-18-2024
02:52 PM
by
Content Cleaner
Hi Constantin,
unfortunately this information is not contained in the CVI 2013 SP1 Bug Fix Information which is supposed to include this patch... maybe you can take care of having the documentation updated?
In addition, the patch documentation is referring to the y axis only...
Thanks ![]()
07-29-2014 04:17 AM - edited 07-29-2014 04:18 AM
I updated CVI 2013 using f1,f2 and f5 patches and it fixed the problem,
Thank you very much!
07-29-2014 04:30 AM
Wolfgang,
You're right, bugs that were fixed in 2013 f1 patch don't appear in 2013 SP1 Bug Fix list. I'll talk to our Application Engineer to see what's going on.
Although the problem was reported for the y-axis, it was more generic.
Constantin
07-29-2014 01:15 PM
Hi Wolfgang,
I added an explicit note to the LabWindows/CVI 2013 SP1 Bug Fix Information page stating it integrates fixes from the LabWindows/CVI 2013 f1 patch. It even links to the patch document
.
In addition to this, I have added a link to the patch details page under the LabWindows/CVI 2013 section of the LabWindows/CVI Release Information document.
Regards,
07-29-2014 02:48 PM
Hi Daniel,
Thanks!
If I may use the opportunity for a suggestion...:
From a user perspective it would be great to have one list that can be searched for open / resolved issues, right now one would need to search several Web sites and, probably, nobody will do... Having just one page would simplify this - and it would not be much effort for NI to implement it ![]()