Hello,

 

Sorry if this is immediately obvious, but:

 

In the documentation for IMAQ Particle Filter 3, it says, "Measurement Type specifies whether the measurement is in uncalibrated pixels or calibrated real-world values." It's a boolean input, but it's not clear to me which is associated with "true," and which is associated with "false."

 

 documentation

Any help is appreciated,

 

Candice

0 Kudos
Message 1 of 2
(3,620 Views)
Solution
Accepted by topic author Candice

Candice -

 

In this case, "true" means calibrated real-world values, and "false" means uncalibrated pixels. I've filed a CAR to make this clearer in a future version.  Thanks!

 