08-10-2011 05:12 AM - edited 08-10-2011 05:15 AM
So I updated to Labview 2010 and the camera I used was plugged out, afterwards my project including image acquisition did not work any more. I could break it down that it all comes from an ImageType error. So, my grayscale camera PGR Scorpion SCOR-20SOM in MAX gives me an 32bit RGB image, whereas in FlyCap everything is normal and it shows 8bit Gray.
How can I make it work again?
(Converting each picture back to 8bit Gray would be kind of crazy as it should just come as 8bit)
I tried the 2.0.314, 2.3.3.14, 2.3.3.17 and 2.3.3.0007 FirePRO driver (it's a 1394-camera)
08-10-2011 09:51 AM
Solution: Choose the Microsoft Firewire driver instead of the FirePRO from Greyscale, in the device manager deinstall the camera device, and reinstall it in MAX with right-click option NI-IMAQdx IIDC Digital Camera