Dear Forum,
We have a serious problem getting the SONY XCL-X700 camera going together with the PCI-1426. Even when using the MAX-software we are not able to establish serial connection.
When we try this we get the following message:
Error 0xBFF60092
The requested serial termination string was not found in the return buffer.
It seems like the .icd-file of the Sony XCL-X700 does not implement the correct serial protocol.
If we change in the .icd the following:
TermChars (OK\n\r) -> TermChars (\x06)
Then it seemed that the "Termination string" was solved, but now we got the following error message:
Error 0xBFF60093
The serial read did not complete within the specified timeout period.
The used baudrates were 38400 and 19200.
These are the first lines of the used .icd-file:
CameraFile (5.50) {
Manufacturer (Sony)
Model (XCL-X700)
CreationDate (20050216102252)
Is there somebody who can help us with this issue?
Kind regards,