IMAQ Get LCD and USB Camera

Hello 

I have a problem with block IMAQ Get LCD and USB Camera . I saw the example with this block but it works only with image. I create program but all the time i recivet te Invalid ROI error. Maybe someone created a similar program  and knows what is wrong. I would be grateful for help. I attached my program. 

 

Best Regards 

Download All
0 Kudos
Message 1 of 8
(5,271 Views)

This is not the right board for asking questions.  I'll ask the moderator to move it to the Vision board for you.


GCentral
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines
"Not that we are sufficient in ourselves to claim anything as coming from us, but our sufficiency is from God" - 2 Corinthians 3:5
0 Kudos
Message 2 of 8
(5,268 Views)

Thank You

0 Kudos
Message 3 of 8
(5,261 Views)

Maybe someone have an idea ?? 

0 Kudos
Message 4 of 8
(5,246 Views)
0 Kudos
Message 5 of 8
(5,223 Views)

I read, I think something else is the problem, but i don't know what 😕

0 Kudos
Message 6 of 8
(5,217 Views)
Check the ROI descriptor values:
The values in the array in sequence are Top,Left,Bottom,Right,.
-According to IMAQ Read LCD, the minimum ROI Size should be 95x87.
-Which means you should take your ROI values such that they make larger region than 95x87.
-What are the ROI values you are taking? from screenshot i am seeing one value, from vi different, please make sure they are above the required ROI
Thanks
uday
0 Kudos
Message 7 of 8
(5,210 Views)

I changed the ROI parameters. In the first iteration of program the cameras try  to  find  the LCD display. The program reads  the different numbers sometimes, but labview  gives an error that this is the wrong LCD or LED display. . Suddenly the program turn off  and when i turn on the program again I recived the error from image. (Hex0xBFF6901B) Timeout.  What is wrong ?? (I turned off the windows barrier ant antyvirus)

If i want to read the data from display, the display need to be in the area cerated in ROI?? 

If I approach the display too close to the camera the IMAQ Get LCD will not work?? 