Hello,
we are currently using an IMAQ PCI 1422 board connected to a CCD. In order to program this CCD we are using three of the external trigger lines to program the device in a serial way. External trigger #3 is wired as input data line from the CCD. I can successfully program the CCD, but I can not read back its response on External trigger #3.
I'm using imgSessionTriggerRead from the IMAQ library under Visual C++. The response on the scope we hooked up to our setup shows that the CCD gives the right data pattern back onto External trigger #3 but for some reason I do not get reliable read-outs using imsgSessionTriggerRead. Does this function only respond when the signal transitions from high to low or vice versa or can you directly read the current logic level of the trigger line. The help provided in the manual is a bit confusing.
Thanks in advance,
Michiel Bronswijk