08-11-2006 10:03 AM
08-15-2006 05:38 PM
08-16-2006 05:31 PM
Hi Mike-
Thanks for the reply. This is a common question in mail sorting/verification applications. If it is taking too long (sometimes they set it to 50ms) then they want to kick it offline as a fail. What do you think about the idea of using the pulsed timed outputs. I could set a pulse output to go high after a set time like 50ms which could override the pass/fail outputs. Let meknow what you think.
Thanks,
Steve Mleczewski
Industrial Logic
08-17-2006 09:40 PM
08-30-2006 07:27 AM
Yes, in a way I'm trying to intercept the pass/fail signal if the inspection is taking too long. If it is taking too long to figure out what the OCR characaters are it is probably bad print anyway.
Thanks,
Steve Mleczewski
Industrial Logic
08-31-2006 01:27 PM