invalid parameter #3

I get invalid parameter #3 trying to snap or grab using 60 pregressive ccd with imaq 1409.
I use Visual basic imaq ocx.
0 Kudos
Message 1 of 3
(3,273 Views)
Try upgrading your .ocx files to the latest version. You can find this for free download on our website at:

http://digital.ni.com/softlib.nsf/websearch/B31BF682408764E086256B120071D909?opendocument&node=132060_US

This was a known issue with earlier versions of the .ocx file and is fixed in the 6.0.5 version.

Jack Arnold
Application Engineer
National Instruments
0 Kudos
Message 2 of 3
(3,273 Views)
I upgraded to IMAQ 2.5.3 without success,
and I also upgraded the OCX as suggested here,

Problem solved. Thank you.