Measurement Studio for .NET Languages

cancel
Showing results for 
Search instead for 
Did you mean: 

Timestamping IRIG

 

We have a PXI chassis with 5x NI-6255 and 1x NI-6682 with an IRIG generator providing time to the NI-6682. Is it possible to have the timestamp information from the data collected by the NI-6255's to be the IRIG time instead of the system time? I have been searching for a while now trying to do this but I have been unsuccessful.

 

Any help would be greatly appreciated.

0 Kudos
Message 1 of 2
(5,344 Views)

I've been looking to and I haven't seen a way to do that. It looks like it only pulls it from the system time.

TimC
National Instruments
Applications Engineer
0 Kudos
Message 2 of 2
(5,329 Views)