Salve a tutti,

sono nuovo al mondo di VB6.

Sto scrivendo il codice in VB6 per acquisire dati da una scheda DAQPad-6015 (per ora sto utilizzando un simulatore offerto da Measurements & Automation). Il mio problema e che non riesco a capire i parametri di DAQmxReadAnalogF64. In pratica dovrei campionare ogni 0,1 sec 10 campioni. vi posto il codice

 


Option Explicit
Dim running As Boolean


Public Sub cm_Click()
Dim myTask As Long
Dim y As Variant
Dim data(100) As Double
DAQmxErrChk DAQmxLoadTask("voltaggioFV", myTask)

running = True

Do While running
DAQmxErrChk DAQmxReadAnalogF64(myTask, 100, 10, DAQmx_Val_GroupByChannel, data(0), 100, 100, ByVal 0&)
CWGraph1.PlotY (data)
Label1.Caption = data(0)
'Label3.Caption = data(99)

y = CWDSP1.BwLPF(data, 50, 10, 3)

CWGraph2.PlotY (y)

 

Timer1.Interval = 2000

Open "c:\File.txt" For Append As #1
Write #1, Time; Tab(35); data(0)
Close #1


DoEvents
Loop

DAQmxErrChk DAQmxStopTask(myTask)
DAQmxErrChk DAQmxClearTask(myTask)


Exit Sub
ErrorHandler:
DAQmxStopTask myTask
DAQmxClearTask myTask
MsgBox Err.Description
End Sub

 

Public Sub Timer1_Timer()

Timer1.Enabled = True

Label2.Caption = Time
Open "c:\File.txt" For Append As #1
Write #1, Time
Close #1

End Sub

 

Private Sub cmd_Stop_Click()
running = False
Timer1.Enabled = False
End Sub

 

Vi ringrazio

 

Buona Domenica

 

Andrea

0 Kudos
Message 1 of 8
(9,086 Views)

Ciao Andrea,

 

puoi trovare tutte le informazioni sui parametri utilizzati dalla funzione DAQmxReadAnalogF64 nell'Help del driver DAQmx:

da Start >> Programmi >> National Instruments >> NI-DAQ >> Text based code support >> NI-DAQmx C Reference Help ed esegui una ricerca per la voce "DAQmxReadAnalogF64"

 

Serena

0 Kudos
Message 2 of 8
(9,074 Views)

Grazie per la celerità nella risposta,

purtroppo la ricerca non da nessun risultato. Ho cercato su internet ma niente.

Mentre posto ti chiedo un altra cosa, io filtro il segnale in ingresso con un filtro Lowpass Butterworth. Graficando il segnale filtrato me lo inverte, ossia se il grafico del segnale va da 0 a 100 il filtro mi grafica da 100 a 0.

 

Grazie Serena

0 Kudos
Message 3 of 8
(9,070 Views)

Mi pare strano che tu non abbia trovato nulla, inserendo la voce "DAQmxReadAnalogF64" nel tab Search trovi la seguente pagina:

 

DAQmxReadAnalogF64

int32 DAQmxReadAnalogF64(TaskHandle taskHandle, int32 numSampsPerChan, float64 timeout, bool32 fillMode, float64 readArray[], uInt32 arraySizeInSamps, int32 *sampsPerChanRead, bool32 *reserved);

Purpose

Reads multiple floating-point samples from a task that contains one or more analog input channels.

Parameters

Input
NameTypeDescription
taskHandle TaskHandleThe task to read samples from.
numSampsPerChan int32The number of samples, per channel, to read. The default value of -1 (DAQmx_Val_Auto) reads all available samples. If readArray does not contain enough space, this function returns as many samples as fit in readArray.

NI-DAQmx determines how many samples to read based on whether the task acquires samples continuously or acquires a finite number of samples.

If the task acquires samples continuously and you set this parameter to -1, this function reads all the samples currently available in the buffer.

If the task acquires a finite number of samples and you set this parameter to -1, the function waits for the task to acquire all requested samples, then reads those samples. If you set the Read All Available Samples property to TRUE, the function reads the samples currently available in the buffer and does not wait for the task to acquire all requested samples.
timeout float64The amount of time, in seconds, to wait for the function to read the sample(s). The default value is 10.0 seconds. To specify an infinite wait, pass -1 (DAQmx_Val_WaitInfinitely). This function returns an error if the timeout elapses.

A value of 0 indicates to try once to read the requested samples. If all the requested samples are read, the function is successful. Otherwise, the function returns a timeout error and returns the samples that were actually read.
fillMode bool32Specifies whether or not the samples are interleaved.
ValueDescription
DAQmx_Val_GroupByChannel  Group by channel (non-interleaved)
DAQmx_Val_GroupByScanNumber  Group by scan number (interleaved)
arraySizeInSamps uInt32The size of the array, in samples, into which samples are read.
reserved bool32 * Reserved for future use. Pass NULL to this parameter.
Output
NameTypeDescription
readArray float64 [] The array to read samples into, organized according to fillMode.
sampsPerChanRead int32 * The actual number of samples read from each channel.

Return Value

NameTypeDescription
status int32The error code returned by the function in the event of an error or warning. A value of 0 indicates success. A positive value indicates a warning. A negative value indicates an error.

 

Per quanto riguarda il filtro, potrebbe dipendere dai parametri che utilizzi. In particolare che funzione usi per implementare il filtro?

 

Message Edited by reikira on 03-08-2010 03:47 AM
0 Kudos
Message 4 of 8
(9,066 Views)

La funzione del filtro è questa

 

y = CWDSP1.BwLPF(data, 50, 10, 3)

 

CWGraph2.PlotY (y)

 

 

Ma per quanto riguarda il DAQmxReadAnalogF64 come gestisco input contemporanei da più canali dello stesso Device all'interno dello stesso task?

Ho provato a creare tanti task quanto i canali ma se li faccio partire contemporaneamente mi stampa a schermo "Specifiche riservate".

0 Kudos
Message 5 of 8
(9,060 Views)

Ricevi l'errore di Risorsa riservata perchè per ciascuna scheda puoi creare un solo task dello stesso tipo (un solo task di AI, uno di AO, ecc), ma all'interno del task puoi creare più canali, per esempio

 

DAQmxErrChk (DAQmxCreateTask("",&taskHandle));
DAQmxErrChk (DAQmxCreateAIVoltageChan(taskHandle,"Dev1/ai0:2","",DAQmx_Val_Cfg_Default,-10.0,10.0,DAQmx_Val_Volts,NULL));

 

così crei i canali dallo 0 al 2.

 

Puoi trovare degli esempi di acquisizione dati in Start>> Programmi >> National Instruments >> NI DAQ >> Text-based Code support

0 Kudos
Message 6 of 8
(9,047 Views)

Scusami ma mi sono spiegato male. Io ho un task all'interno del quale ho 4 canali fisici (2 corrente e 2 tensione). Devo creare un interfaccia in Visual Basic 6 che  legge dai 4 canali e grafica i valori nella stessa frame.

Come faccio nella frame a leggere contemporaneamente dai 4 canali e scindere i valori delle correnti e tensioni per graficarli?

 

Grazie per l'aiuto

0 Kudos
Message 7 of 8
(9,040 Views)

Ti allego una sorta di schema. al click sul Bottone dovrebbe leggere dai canali e graficarli (come ho postato sopra)

 

Buona Serata

 

AndreaImmagine.JPG

0 Kudos
Message 8 of 8