Hello,
Make sure you are powering the UMI-7764. Are you able to get your motor to move when you give it a target position in Measurement and automation explorer (MAX)? Also, you can check the step and direction line during motion. When you move forward you should see the direction line going one way (high to low) and then as soon as you give the target position to move backwards the direction line changing and going (low to high). Also you should notice a pulse on the step line.
There is also a inhibit output line on the UMI which can be tested. If you toggle between kill and halt in MAX, you should notice the output on the inhibit line also toggling. Most of the drives have an enable line which is connected to
the inhibit output line and needs to be enabled in order for the drive to provide power to the motor. Are you in open loop or closed loop mode?
Please let me know if you have further questions.
Good luck and have a great day!
Koninika
Applications Engineering
National Instruments
03-28-2006 10:39 AM - edited 03-28-2006 10:39 AM
Message Edited by denyart on 03-28-2006 12:28 PM
03-29-2006 02:32 PM
03-29-2006
11:37 PM
- last edited on
11-11-2025
11:40 AM
by
Content Cleaner
[broken link removed]
03-31-2006 11:09 AM
04-01-2006 03:38 PM
04-03-2006
01:32 PM
- last edited on
11-11-2025
11:40 AM
by
Content Cleaner
Hi,
The best place for answers to your instrument control questions would be the Instrument Control (GPIB, Serial, VISA, IVI) forum. You should be able to find the answers to your questions about controlling your o-scope there.