Hi Thomas -
The answers to your questions will ultimately lie with Servostar's documentation, since you're asking about the inputs expected by the drive and the outputs provided by it. However, I'll try to help out with knowledge of our products:
- The command output from our motion control devices (the 73xx line) is a +/- 10V DC signal, whose level is directly proportional to the command given. A velocity drive should interpret this command accordingly, though you'll have to check with Servostar to see what type of command signal they expect.
- Our motion controllers generally receive encoder or analog feedback signals directly from the feedback device, and not from the drive. If the Servostar drive provides feedback, you can read it in using the Analog Input (for voltage feedback) or Counter Input (for encoder feedback) channels on your DAQ device.
David Staab, CLA
Staff Systems Engineer
National Instruments