04-30-2008 10:40 AM
05-01-2008 03:13 PM
Hi Jeff,
Are you using examples that shipped with your software? If not, I suggest using the examples that we’ve made and provide to you for free as a starting point. It seems you’re using CVI and there are examples that do AI and AO and all you would have to do is put them together into one application. You can find example programs here.
I tried to duplicate your phase delay,
but was unable to do so. There is a finite slew rate for the output sample to reach
the specified level, but for your device it is 15V/us, so unless you’re
sampling at rates your card is not capable of, your input should not be off by
more than 1 sample due to slewing. I guess there’s a caveat that if you’re
using a really long cable, you could end up being delayed by more than one sample.
I think a better approach at this point
is for you to explain a little more about your application and also share in
more detail what you’ve done to tackle the issue you’re seeing. This will help
the community understand how best to go about what you’re doing.
In addition to our Developer Zone, you can find more resources
at NI Developer Zone Community, found by visiting ni.com/community or
ni.com/devzone and clicking the link in the upper-right.