I was wondering if I can have 4 independently-timed analog output waveforms from the NI 9265 installed in the NI cDAQ-9178? My application is very similar to the 'Cont Gen Current Updates Wfm-Int Clk.vi' example. However, I would like to use the 'Continuous Samples' / 'Use Waveform' options of the DAQmx Timing VI but supply 4 different delta-t (dt) values. What is the best way to do this?
12-04-2012 06:12 PM
Hi RickyB,
The cDAQ-9178 has three analog timing engines, however they can only be used simultaneously if they're used in separate modules. Assuming you're only using a single 9265 module, you will only be able to use one sample clock.
Hope this helps.
12-07-2012 05:27 PM
3 analog *input* timing engines.
Even with multiple 9265s there is still only one analog output timing engine.