ā03-08-2010 11:21 PM
Solved! Go to Solution.
ā03-09-2010 12:03 AM
The trial version of what? Is that LabVIEW and is so, which version of LabVIEW?
TDMS exists in LabVIEW from LabVIEW 8.2.
And what TDMS VIs? Would you please supply the full name of the TDMS VIs?
Thank you.
ā03-09-2010 12:10 AM
ā03-09-2010 12:32 AM
Thanks, I see. These TDMS VIs should exist from DAQmx 9.0, but I'm not sure whether it exists in trial or base version of DAQmx.
I forwarded your question to our DAQmx colleagues.
ā03-09-2010 12:33 AM
ā03-09-2010 10:36 AM
The ability to use DAQmx to log to TDMS is limited to DAQmx and is not supported in DAQmx Base. In order to use this functionality, you'll need to use DAQmx.
Regards,
ā03-09-2010
11:21 AM
- last edited on
ā06-17-2024
09:33 AM
by
Content Cleaner
If your effort was to use a smaller version of DAQmx so that you can deploy applications, the DAQmx Core Runtime Engine is smaller than the full installation: http://joule.ni.com/nidu/cds/view/p/id/1616/lang/en (Note, however, that this installation will not install the full LabVIEW support; it installs support for pre-built executables that you created from LabVIEW.)
As well note that the core runtime engine does not install TDMS; so if you do use this option, please ensure that you include TDMS in your application's installer (or install it separately on your target machine).
ā03-13-2010 02:12 AM
ā03-13-2010 06:48 PM
ā03-14-2010 01:09 AM