01-25-2011 12:58 AM
I am interested in acquiring voltage signals from a probe.I am using PCI-6143 S-series NIDAQ. My requirement is such that I must acquire voltages only above a certain level.I have tried to use the NIDAQmx triggering task but it fails giving error code -200077. and the description says im allowed select only digital edge triggering.
Please help.
Thanks in advance
Solved! Go to Solution.
01-25-2011 01:52 AM
Hi shirsha,
in fact the message you get is proper, as NI 6143 Specifications says that this board supports just digital triggering. You can find list of S series devices which supports analog triggering here: Which S-Series (61xx) Devices Support Analog Triggering?, or you can use some external circuity as analog signal comparison.
regards,
stefo