A trigger is an external stimulus that initiates one or more instrument functions. Trigger stimuli include a front panel button, an external input voltage pulse, or a bus trigger command. The trigger may also be derived from attributes of the actual signal to be acquired, such as the level and slope of the signal.
A trigger is not a clock.
If you want acquire with a specific clock, I advise you to use external clock. Instead of using your signal as trigger, use it as external clock.
Have a look at "Cont Acq & Graph Ext Scan Clk - D trig.vi" example. This example is provided with LabVIEW (Help >> Example Finder).
Here a tutorial about external clock acquisition :
http://zone.ni.com/devzone/conceptd.nsf/webmain/7d8eaea1d87cfb2686256802007b8c52?OpenDocument
Regards,
Isabelle
Ingénieur d'applications
National Instruments France