Hi!
I am using a USB-6009 and have connected the digital output to the analog input (and the digital ground to the analogue ground) in order to test the digital output. The analog input has been tested with a function generator and is measuring correctly.
I find that although I get a signal with a peak-to-peak amplitude of 5V, relative to the ground, the signal changes from -1.45V to 3.55V. I need to generate 5V pulses (0V to 5V relative to ground) in order to control a stepper motor. Please could you let me know how to change this?
Many Thanks
Mark