07-31-2021 10:37 AM
Hello all, I've been running into an inconsistency between the bode plot and AC Sweep. If I'm not mistaken they should do the same thing.
I have a two stage band pass Butterworth filter with cutoff frequencies of 0.05 and 40 Hz.
Running a bode plot and AC analysis both show cutoff frequencies as desired. However, the bode plot has a gain in the band pass of 8dB, while the AC analysis has a band pass gain of 28 dB, What gives?
07-31-2021 01:33 PM
Nevermind, found the source of discrepancy, it was the usage of the function generator by the AC Sweep while Bode plot used the AC source.