NI TestStand

cancel
Showing results for 
Search instead for 
Did you mean: 

Error, TDMS Set Properties LabVIEW: Storage VIs internal error. [Error Code: -2500, User-defined error code.]

Hi,
 
I have a VI that works fine with LV8.2 adapter in TestStand 3.5.
 
When I want to use LV runtime adapter I receive the following error:
 
Error, TDMS Set Properties in SetExecutionPropertiesToTDMS.vi->Measure Analog Inputs.vi LabVIEW: Storage VIs internal error. [Error Code: -2500, User-defined error code.]
 
SetExecutionPropertiesToTDMS.vi is attached.
 
Any help is appreciated,
 
Andras
 
 
0 Kudos
Message 1 of 2
(3,945 Views)
Hi Andras,

if you install DAQmx 8.5 with LabVIEW 8.2 the LabVIEW Run-time Engine 8.2 would replaced
with Run-time Engine 8.2.1., which causes a problem with the TDMS API used in a stand alone
executable respectively used with LabVIEW Run-time Adapter.

You have two solutions, one is to update LV 8.2 to LV 8.21 or you deinstall DAQmx 8.5 and the LabVIEW Run-time Engine 8.21.
After uninstalling , reinstall DAQmx 8.3

I attached msiblast, to uninstall the LabVIEW Run-time Engine 8.21 and DAQmx 8.5

best regards.
Christoph Strasser|NIG AE
0 Kudos
Message 2 of 2
(3,934 Views)