Mass Compile :TestStand - Default Values 90.llb ???

Hi, 

I'm using Labview 2009 and TestStand 4.1.1(using the Labview Runtime Engine 9.0 Adaptor), and get the following error when running my sequence file:

 

Error, The support VI 'C:\Documents and Settings\All Users\Documents\National Instruments\TestStand 4.1.1\AdapterSupport\LabVIEW\TestStand - Default Values 90.llb\TestStand - Get Control Default Value.vi' might not be up to date. Please update llb file to the most recent LabVIEW version. LabVIEW: VI version is too early to convert to the current LabVIEW version. [Error Code: -17500, Operation Failed.]

 

As I did not have this llb, I've copied and renamed the "TestStand - Default Values 86.llb". 

After opening TestStand - Default Values 90.llb, Labview does not allow me to save the changes as it is password protected.

 

 

Anyone have any advice on this matter?

 

Thanks

0 Kudos
Message 1 of 2
(3,222 Views)

Are you sure it is not just Read-Only?  I noticed my previous versions 'TestStand - Default Values 90.llb' was read only, I had to change that and then update for the VI for LV 2010.  Renamed it to TestStand - Default Values 100.llb.

 

Try opening the LLB directly, I have never had any problems doing this.

 