07-02-2010 07:24 AM
Hi, I have a Message Popup with four buttons. Button 1 is the Timeout Button with a Time to Wait of 10 seconds. It works fine with the development machine but when I deploy the sequence the Popup does not wait the required 10 seconds. It pops up and closed down immediately operator does not get time to select a button. Using TestStand 4.2.1 with the CVI operator interface.
Thanks in advance
07-02-2010 04:54 PM
Have you tried installing on a different machine (preferrably different hardware)? Your machine might have the problem mentioned here:
http://forums.ni.com/t5/NI-TestStand/Wrong-Wait-step-execution-time/m-p/862246#M23289
Hope this helps,
-Doug