Hi Paul,
In the description of your problem you state that "I will have to remove it before I can build the application". I was wondering if you could elaborate on the scenario you are describing because this is a little bit confusing to me as it is. The "Assemble Test VIs for Run-Time Distribution" tool in the Sequence Editor does not involve "building an application" as part of the process of using it. When you select the menu option for this tool, a TestStand sequence is invoked that has a few LV VI steps in it which perform the VI Assembly process, with no application building involved (just searching through sequences for top-level vis, their sub-vis, and copying them all into a directory you choose). I hope this describes what it is I'm not understanding about your statement, but to explain why it is that I feel this is important is in order to reproduce the problem I need to know exactly what it is you are doing at the time of encountering the problem. To go over a common set of issues people encounter when they use this tool, I would like to see if you have tried the following:
1) Have you checked to make sure that the LabVIEW Standard Prototype Adapter is configured to use the LabVIEW development environment as its Run-Time Server before running the tool. It will not work if the adapter is set to use TestStand LVRTS or TestStandGUILVRTS. The assembly tool requires features of the full LV IDE to perform the functions it carries out, and you will get an error if the adapter is configured improperly. To check this out, go to Configure >> Adapters..., select the LV Adapter in the listbox, then click the Configure button. In the second dialog, change the run-time server option to "LabVIEW".
2) Are you actually trying to build the Assemble Test VIs for Runtime Distribution tool into an application? (This is not an intended use of the tool's VIs).
3) Before running the assembly tool, have you tried using the Sequence Editor's File >> Unload All Modules option?
Let me know if you have tried the above things or if you are doing any of the "unintended" things with the tool so I can get a better grasp of when it is you are seeing the problem. Again, the goal would be for us to reproduce it.
Jason F.
Applications Engineer
National Instruments
www.ni.com/ask