Hello All

 

I have several TestStand codes for different products, I store each product's TestStand VIs in a separate folder. So when working on one product I don't change the other product's VIs. Or that's what I hope for.

 

Below are my different products in a separate folder:

 

1.png2.png

 

Last week I worked on Proloc II_Full_Test_01_22_A_01.seq and got everything to work.

Today I worked on another product (NC_Relay). Then out of curiosity, I opened Proloc II_Full_Test_01_22_A_01.seq again to see if it still runs. Now there are VI's missing. It happened in the past as well. Every time I change to another product the other product gets messed up.

 

I don't understand why. Each product's VIs are in separate folders. The only common VIs are the OMICRON driver VIs (See below)

 

3.JPG

 

What can I be doing wrong, see the Error I get in TestStand. Below

 

4.jpg5.png

 

 

 

0 Kudos
Message 1 of 4
(815 Views)

This sounds rather like a file organization issue....

 

Are the VIs organize in an lvlib for each product? Do some product folders contain VIs with the same name?

Message 2 of 4
(795 Views)

Hello Oli

 

Not sure what lvlibs are, don't think I use it.

The VIs are duplicated in each product folder, so yes most VIs have duplicate names.

 

Marinus

0 Kudos
Message 3 of 4
(790 Views)

I guess, what you are experiencing is an effect of the following: LabVIEW differentiates VIs by name. And it can only have one single VI with a given name loaded in memory at a time.

 

What could've happend is, that you had two instruments loaded at a time an referring to a VI in their respective folder but with the same name. Only one got loaded and one of the instruments got changed. Maybe there was a Save As dialog (which can also acta as a file move) and you accidentally removed one of the VIs.

 

You can circumvent issues like this by using lvlibs https://www.ni.com/docs/de-DE/bundle/labview/page/using-libraries-in-labview-projects.html

since they will create namespaces and allow you to load two files which would otherwise be conflicting.

 

0 Kudos