StationGlobals, remote view

Hi,

 

On viewing the StationGlobals, in Test Stand 2.0.1, on a test station locally I can see all.

 

When I view the same sequence remote I cannot see at least one of the StationGlobals.

 

Environment setup is the same for both PC’s.

 

“Show Hidden Properties” dose not help!!

 

How do I get the vies all StationGlobals from the remote PC?

 

Thanks for the help

 

Simon

 

0 Kudos
Message 1 of 3
(3,019 Views)
StationGlobals are globals specific to one PC.  The are not shared when you transfer sequence files (like a sequence global).  It may be that one of the station globals on the remote PC got deleted.  The station globals are stored in StationGlobals.ini.  If you think they are the same but teststand is hiding something, you could also compare the .ini files but I think you will find that they are not the same.
0 Kudos
Message 2 of 3
(3,012 Views)

Hi,

 

Thanks for that.

 

Would this also be the case if  on the network I open the sequence file on the remote PC, this is how I am doing it?

 

Will it still use the local PC ini file?

 

Thanks for the help

 

Simon