09-18-2008
10:42 AM
- last edited on
09-10-2025
03:38 PM
by
Content Cleaner
National Instruments has fixed an issue with LabVIEW 8.6 and TestStand where selecting a LabVIEW step in TestStand can cause a hang of several seconds. The issue is described in more detail in Known Compatibility Issues with TestStand and LabVIEW 8.6 and can be fixed by downloading the LabVIEW 8.6f1 Patch.
09-19-2008 01:42 AM
Hi,
I have tested the patch now and it seems to solve my problems. Thank you for working on this issue with high priority, I really appreciate it!