Scott,
Your ProcessSelectedSteps sequence has been very helpful. I have modified my version of it to access and change other properties besides RecordResults. Do you (or anyone else reading this) know how to read and change limits of several selected sequence steps all at once. I have not been able to find the limits property within the TestStand ActiveX object. My reason for wanting to do this is the following: I have several sequences that do not use the property loader but instead have the limits hardcoded in them. My plan is to export the limits to a spreadsheet and then use the property loader to load those limits. Then I would like to change the hard coded limits to something that is guaranteed not to pass (e.g. 1 < x < -1). That way we'll know for sure that all those steps are using the spreadsheet limits as the steps would fail otherwise.
07-17-2006 03:10 PM
I figured out the answer to my own question. I've attached the Sequence. To install see reply 5 of this thread. I make no guarantees about this utility but it works for me. This is for TestStand 2.