NI TestStand

cancel
Showing results for 
Search instead for 
Did you mean: 

scode failure when executing test uuts

I'm getting an scode failure when executing the "test uuts" for my sequence. The station was working earlier so I'm not sure what happened. The test dialog starts then I get and error promt stating
 
Scode = 0xffffbc65
 
Description unknown type name '1'
error accessing item 'ModelOptions(1).NumTestSockets'
 
Has anyone seen this type of error before? I eneabled tracing and it looks like it hangs up at the "read model options defaults" dll.
0 Kudos
Message 1 of 3
(3,145 Views)

Hi,

Is it possible to post a JPG of the Error Dialog.

Regards

Ray Farmer

Regards
Ray Farmer
0 Kudos
Message 2 of 3
(3,128 Views)
Hi Jblpep,

Which process model are you using, and have you modified the process model at all?  If you have modified the process model, do you still have the original copy to see if the original process model still runs? If you do have the original and it does still run properly, I would recommend trying to diff your process model with the original NI process model to see if anything is different.
Pat P.
Software Engineer
National Instruments
0 Kudos
Message 3 of 3
(3,103 Views)