06-16-2025 04:24 PM
NI PXI-1033 does not show up in NI MAX. Shows up as unidentified chassis, and then PXI-1033 is not avialable from the drop down list.
I have five PXI cards that are showing up in max, but unable to communicate with them as they are not under the PXI chassis in the tree.
My SW versions are included in the screenshots.
Windows 11 x64 OS.
Solved! Go to Solution.
06-24-2025 08:57 AM
I have solved this issue. Installing version 15.0 of NI 488.2 (GPIB, USB) allowed the chassis to show up as well as alleviate a very slow loading process within NI MAX.