RT & Traditional Drivers

I am trying to use a PXI-8186 in the Real Time mode.  I have 6 PXI-4472 modules, and one PXI-5411 module installed in a PXI-1045 Chassis.  I am using LabVIEW 8.0.1 with Real Time 8.0.1, NI-DAQ 8.0.1 along with NI-DAQ 7.4.1 Traditional Drivers installed.  Using MAX I am unable to locate any Traditional Devices.  Does RT support Traditional Devices and if so how do I active them.
0 Kudos
Message 1 of 2
(3,834 Views)
Traditional DAQ devices are supported in RT, however they will not show up under Devices and Interfaces due to the architecture of the Traditional driver.  You can find these devices in MAX by going to Tools > Traditional NI-DAQ Configuration > Remote DAQ configuration.

--Paul Mandeltort
Automotive and Industrial Communications Product Marketing
0 Kudos
Message 2 of 2
(3,825 Views)