teststand 3, PXI and IVI Driver Versions

I believe that I have a problem with the installations that were apparent when using Teststand 2 and IVI drivers.
We have a Teststand 3 system, with a PXI chassis, and a PXI-4070 DMM and a PXI-2567 DMM.
When I try and call the PXI DMM from Teststand through the IVI step type I get the following messge:
Error Executing substep 'post'. An exception occurred calling 'Run Step' in 'ISubstep' of 'Teststand IVI Step Types'.
An error occurred while executing the step.
Component Works IVI control editor. The IVI Init operation failed for logical name 'JoyDMM'
-31619; User-defined error code.
Step 'IVI DMM' of sequence' Mainsequence in 'Sequence File 1'
I have attatched the NI Software file from Max for Debug
0 Kudos
Message 1 of 2
(3,038 Views)
ADL,

Have you tried communicating with those devices in MAX using the logical names? It seems that the logical name for JoyDMM isn't recognized within TestStand which probably means they aren't recognized in MAX either.

Let us know what you find.

Regards,
Shannon R
Applications Engineer
National Instruments
0 Kudos
Message 2 of 2