07-07-2005 05:53 AM - edited 07-07-2005 05:53 AM
Hi Andy,
I have done more checks on the vi that you sent and that which was developed yesterday, since these are closer to what we are looking for. Your vi was run as it is and the spectrum checked, we see that the deviation is not at the required 1.2 and 1.8 Khz form the carrier of 10Mhz instead it is at 300Hz, the same was observed with the vi that i have posted earlier, when observed using an external oscilloscope too we observe the same, this exercise was done to alleviate doubts of sampling and such similar parameter setting errors which may cause aliasing.
I was wordering about a second method of doing the upconversion since I am stuck with that for now.
Since we have a way to generated the continuous phase FM signal manually (see attached vi.) we no longer need to modulate our message signal, the manually generated signal is at a freq of 1.2Khz and 1.8Khz according to the message bits and they are seemlessly connected together,
The method:
We separately generate this signal using the ARB PXI-5421 and us the upconverter PXI-5610 separately
to just upconvert the baseband to the required carrier.
I have started to work on this parallelly, am now at the stage of generating the FM from the ARB independently, there are two waveforms, one of 64 points/bit the other 200 points/bit,the waveforms were checked and seems ok. NOw the need is to upconvert this waveform to the req carrier without further manipulation on this data, say, by just setting the upconverter to 100MHz, and take out the RF signal from the PXI 5610. Can this be done as simply as that or are there any more loop holes!
Pls revert back on this too.
thanks and regards,
sunil
Message Edited by Sunil Rajanna on 07-07-2005 06:02 AM
Message Edited by Sunil Rajanna on 07-07-2005 06:02 AM
07-07-2005 12:07 PM
07-08-2005 01:23 AM