Real-Time Measurement and Control

cancel
Showing results for 
Search instead for 
Did you mean: 

Datalight Reliance v2.10.1053

I am using a cRIO-9082.  It's been working fine for a few days running various file I/O and I/O operations.  We did a power cycle and then on startup it gave the following error to the console (VGA) monitor

 

Transferring control to user program
Datalight Reliance v2.10.1053
Copyright (c) 2003-2006 Datalight Inc.
Reliance v2.10 Build 1053: Assertion failure in module rlinode.c line 1138 (DCL=351)

 

I tried the various dip switches and can go into the BIOS but none get me past this.  Any ideas?

 


Certified LabVIEW Architect, Certified Professional Instructor
ALE Consultants

Introduction to LabVIEW FPGA for RF, Radar, and Electronic Warfare Applications
0 Kudos
Message 1 of 9
(7,057 Views)

Hi Terry_ALE,

 

I think a reformat would be a good step to try out.  This Knowledge Base article should be beneficial:

 

http://digital.ni.com/public.nsf/allkb/DD1B72485DA949158625784F005DCEF6

 

Regards,

Joel I.
Applications Engineer
National Instruments
0 Kudos
Message 2 of 9
(7,030 Views)

Hi Joel,

Thanks for the link.  I am working on this with NI Support but thought it would be good to get this posted in case others encounter this (Google searches didn't have anything on this particular error.

 

We will reformat the device using the instructions on the link.  We will however send it back for a replacement because at this point we are not sure if it is specific to our device.

 

Anything else you come across will be very helpful.

 

 


Certified LabVIEW Architect, Certified Professional Instructor
ALE Consultants

Introduction to LabVIEW FPGA for RF, Radar, and Electronic Warfare Applications
0 Kudos
Message 3 of 9
(7,025 Views)

Hi Terry_ALE,

 

The instructions should still be valid for a cRIO-9082.  

 

I think a reformat is a good first step in resolving this issue.

 

Let me know how it goes!

Joel I.
Applications Engineer
National Instruments
0 Kudos
Message 4 of 9
(7,008 Views)

I followed the procedure and got the same boot error with the following attached to the end:

 

System error KERNEL.446580: Illegal Win32/ETS API from ISR priority

 


Certified LabVIEW Architect, Certified Professional Instructor
ALE Consultants

Introduction to LabVIEW FPGA for RF, Radar, and Electronic Warfare Applications
0 Kudos
Message 5 of 9
(6,981 Views)

Hi Terry_ALE,

 

I think it may be time to RMA this device  You mentioned you were working with NI Support, so work with them to process an RMA for this device.

 

Regards,

Joel I.
Applications Engineer
National Instruments
0 Kudos
Message 6 of 9
(6,974 Views)

We are RMA'ing the device.  Thanks for your help!

 


Certified LabVIEW Architect, Certified Professional Instructor
ALE Consultants

Introduction to LabVIEW FPGA for RF, Radar, and Electronic Warfare Applications
0 Kudos
Message 7 of 9
(6,970 Views)

Hello, i have the same problem in my cRIO-9082.

 

@Terry_ALE did you were able to solve it?

 

thanks! 

0 Kudos
Message 8 of 9
(6,644 Views)

We RMA'd the device and NI said the SSD had to be replaced.  Nothing regarding why this happened.

 

 


Certified LabVIEW Architect, Certified Professional Instructor
ALE Consultants

Introduction to LabVIEW FPGA for RF, Radar, and Electronic Warfare Applications
0 Kudos
Message 9 of 9
(6,639 Views)