01-09-2013 10:50 AM
We are buying a 9870 for our cRIO for RS232 communication. We are not sure what software to use (FPGA & RT). Should we start with http://zone.ni.com/devzone/cda/epd/p/id/2164? This seems to be generic (e.g., supports generic TTL lines). Is there something more specific to the 9870?
Thanks,
Steve
01-10-2013 07:47 AM
We received the 9870 and I was excited to read a flyer saying to install software from ni.com/987x. However, that software refused to install. It complained about requiring Labview 8 and NI-CRIO 2 (I believe). I have Labview 2012 and NI-CRIO 12. I imagine the sw is so old that the version checking is broken.
I found this, which http://zone.ni.com/reference/en-XX/help/370984R-01/lvaddon11/crio-9870/, which looks promising.
01-10-2013 03:13 PM
Oops, the link was supposed to be http://zone.ni.com/devzone/cda/epd/p/id/2164
But that doesn't use any of the 9870 really ...
This seems much close to what we need
http://zone.ni.com/devzone/cda/epd/p/id/6366
I wish this information was included in the 9870 manual somewhere ...
Steve
01-10-2013 06:20 PM
Hi Steve,
The software that the documentation directed you to is for older versions of LabVIEW.
Here is a list of software you need for the NI-987x modules: http://digital.ni.com/public.nsf/allkb/72858E9FE36630B586257458005CF420?OpenDocument
If you have LabVIEW 2012, there was a patch released to fix issues with the NI-987x modules. It can be found here: http://digital.ni.com/public.nsf/allkb/A1DEA3B97FEE3A1086257A8D005898D7?OpenDocument
Here are resources for learning more about using the NI-987x modules:
Using 987x Serial Modules with CompactRIO: http://digital.ni.com/public.nsf/allkb/E6700473687BB0DA862578BE005116B0?OpenDocument
NI 9870 or 9871 Does Not Show Up In FPGA IO Constant: http://digital.ni.com/public.nsf/allkb/9BF90AF3B60A5458862575DE00541F3F?OpenDocument
I apologize for the confusion. Hope this helps!
Regards,
Dayna P.