06-09-2019 10:02 AM
Hi
I am using LabVIEW 2018 SP1 and FPGA module with cRIO9076. When I try to compile the fpga vi the xilinx compiler stuck at Translating for hours with no error. I also tried a very simple vi to test the behaviour . I am using Windows 10 32 bit. can you please point me out to possible cause of that behaviour. is there a compatibility issue?
Thanks
06-11-2019
12:42 PM
- last edited on
12-17-2024
06:34 PM
by
Content Cleaner
Hi,
Have you tried using the compile server? https://www.ni.com/en/support/documentation/supplemental/14/compile-faster-with-the-labview-fpga-com...
Regards,
06-12-2019 03:26 PM
Thanks for the link I have not used the cloud service , I'll give that a try .
06-26-2019
09:31 AM
- last edited on
12-17-2024
06:34 PM
by
Content Cleaner
I would recommend the Compile Cloud Service as well. Any of the Xilinx Compilation Tools for ISE are not supported on Windows 10, but the Vivado tools are. Here's a great article (with a flow chart!) on compatibility with Windows 10. Your behavior is likely being caused by the unsupported configuration.
LabVIEW FPGA Module Compatibility with Windows 10:https://www.ni.com/en/support/documentation/compatibility/17/labview-fpga-module-compatibility-with-...
Hope that helps you get moving on your compilation, and helps you understand why the software was getting stuck!