Need HELP! Sweep frequency using Sound and Vibration Assistant

Hi,

 

I'm new to LabView . I want to do frequency sweep test using Sound and Vibration Assistant. I added the sweep step and chose sin wave frequency as the parameters. I selected frequency  from  1K hz to 10k hz with an increment of 500hz.

 

However, I do not know how to stay at one frequency for a while when sweeping the frequency.  I hope there will be 200 cycles ( or 5 minutes) at one frequency in order to get steady result.

 

Could anyone tell me how to set this? Thank you!

 

 

 

Yue

0 Kudos
Message 1 of 6
(5,589 Views)

Would you be able to post a screenshot of how you are configuring SignalExpresss? What hardware device are you using?

 

-Jayk

RF R&D
National Instruments
0 Kudos
Message 2 of 6
(5,569 Views)

Thank you for your reply!

I am using a shaker connected to the amplifier. Attached please find the plots.

 

Lena

0 Kudos
Message 3 of 6
(5,563 Views)
When someone asks about your hardware, they usually mean your NI daq device.

Please learn some computer fundamentals and take screen shots of the pc and save as png. Silly to use a camera.
0 Kudos
Message 4 of 6
(5,544 Views)

I'm sorry. 

cDAQ-9174

 

0 Kudos
Message 5 of 6
(5,520 Views)

What module are you using in the cDAQ 9174? It's useful to know all hardware devices that are being used.

 

-Jayk

RF R&D
National Instruments
0 Kudos
Message 6 of 6
(5,486 Views)