08-11-2015 01:47 PM
Hi!
N210 box and NI-USRP 14.1 detects WBX and SBX daughterboards correctly and works well.
XCVR2450 is detected as WBX and any NI-USRP API call fails (except "Find.."). What can cause such an error?
~
Gatis
08-11-2015 02:27 PM
Can you run this utility:
C:\Program Files (x86)\National Instruments\NI-USRP\utilities\uhd_usrp_probe.exe
And send the output?
08-12-2015 06:54 AM
I'm really sorry about previous message. Simple SBX board replacement to XCVR2450 solved the problem. Seems this specific board has to have specific touch during attachment. I can not comment what this time I did differently.
Thank you for trying to help!
~
gatis