Hi!, 

 

I want to resample two signals,  one of this, the time and the other the speed. The channels are 1.091.064 values (lenght) and I want to reduce this channels to 60.000 values. What can I do?

 

THank you.

 

Sara

 

 

0 Kudos
Message 1 of 3
(3,897 Views)
Solution
Accepted by topic author s.g.m.

Hi Sara,

 

I assume you want to do the reduction interactively. First of all select DIAdem ANALYSIS. To create a new time channel choose Channel functions >> Generate Numeric Channel and enter the Start value, the End value and 60.000 for the number of values. To resample your existing y channel choose Curve Fitting >> Linear Mapping and enter your "old" x and y channel and your new time channel (LinearGenerated) as the interpolation channel.

 

Regards,

Ralf

0 Kudos
Message 2 of 3
(3,896 Views)

Thanks!!

0 Kudos
Message 3 of 3