02-17-2016 08:03 AM
I am using LabVIEW 2010 and installed LV2010 device drivers and trying to use HSDIO functions, While placing HSDIO function on the block diagram it showing niajel.dll is missing, Can anyone help me in fixing this bug.
I tried uninstalling and installing many times not able to fix.
Solved! Go to Solution.
02-17-2016 10:38 AM
Hello,
I have some questions to ask to help us understand some of the surrounding circumstances for this issue.
Thank you.
02-17-2016 10:44 AM
Hello. niajel.dll is related to NI-TClk although NI-HSDIO does not use it specifically. Are you using some TClk functions?
Also, what other PXI device driver are installed on the system? Could you give a MAX system report?
02-17-2016 10:47 AM
thank you, Kyle for your response:
answers to you questions.
I am using HSDIO 2.0
OS is 64 bit
I am using LV2010 and LV2012 32 bit
Previously it was working fine with 1.9.0 and while updating to 2.0 it is showing some error.
PXI 6556
attached Error information for reference.
Tried uninstalling 2.0 and installing 1.9.0, In 1.9.0 also now it is showing same error in all the labVIEW versions.
What is niajel.dll where it is located?
02-17-2016 10:53 AM
Hi Brian,
Please find the attached report,
02-18-2016 12:35 AM
Brian Thank you,
After upgrading NI TClk, the issue resolved.