Digital I/O

cancel
Showing results for 
Search instead for 
Did you mean: 

NI-9482 leaks AC when the relay is in the open position.

Solved!
Go to solution

Hi, I am trying to use the NI-9482 relay module to open and close a circuit with a 32 kHz square wave (1.6 Vpp amplitude). I am applying the signal to CH0a. When the relay is in the open position, I am expecting minimal leakage on CH0b. However, CH0b is showing over 1 Vpp. BTW, "relay in the open position" in this case means the relay module is not installed on the cDAQ chassis, so it is not getting any power (for controlling relay open/close). I measured the relay resistance in the open position with a DMM, and it shows OL (open circuit). All four channels are behaving the same. Did I purchase a bad part? Or am I doing something wrong here? Has anyone else encountered similar problems with leaking AC signals using this relay module? Thanks.

0 Kudos
Message 1 of 5
(215 Views)

Depending on traces and relay construction, it may be expected, you need to look for isolation specification when relay is open. Unfortunately, it is not listed in specification of 9482.

Found this image online, from the looks of the relay, the contacts must be close enough to capacitively couple signal when open (which you already figured out)

 

santo_13_3-1759658906141.png

 

 

 

For example, PXIe 2520 relay card lists isolation and crosstalks specs.

santo_13_0-1759658461001.png

 

Since Isolation for open channel is not spec'd, I assume this module is not for high frequency "signals", rather to switch loads AC (50/60Hz) or DC and at those very low frequencies the relay is truly open.

Typically, Omron G6K is widely used in the industry and here is the isolation spec for that,

santo_13_1-1759658679674.png

 

 

If you have the means, you can characterize this isolation specification for 9482 or if you have NI technical support, you can request for that data.



 

Santhosh
Soliton Technologies