Thanks Jon.
Unfortunately we can't use DAQmx as we have LabWindows 6.1, which doesn't support it I'm told.
This card is used in some test equipment that we're duplicating, along with other NI cards (6023E's). The original digital card was a 6527, but the web site suggested that the 6514 should be used instead. It never mentioned that we'd need to upgrade our software too!
I'd like to suggest that the website makes it clear which products are only supported by DAQmx, and hence that 'old' LabView and LabWindows environments (i.e. before version 7) just will not work.
For more information on the software and hardware requirements of DAQmx, see http://digital.ni.com/public.nsf/websearch/8DFD2C9085ACB5FC86256D2600817F77?OpenDocument
Mike.
Mike Evans
TRW Conekt
N.I. Alliance Member, UK
http://www.Conekt.net