Hi!

I have a problem with communicating with my Xantrex XTR 300-2.8
power supply. I'm using USB-interface, and my computer creates a
virtual COM-port. I can write and read commands to the power supply
through Hyperterminal, but the commands won't work in LabView when
I try communicating through a VISA-session. Does anyone know a
certain syntax I have to use?

Regards,
Børild
0 Kudos
Message 1 of 12
(6,072 Views)
Hello Børild,
        I recommend downloading and installing the IVI driver for your instrument and then looking at the examples that are part of the LabVIEW wrapper VIs.  The driver developer already went to the trouble of learning the instrument commands and implementing most if not all of them in the driver.  In order to use the IVI driver, you will need to install the IVI Compliance Package.  Let us know if you have any problems.

Cheers,

NathanT
0 Kudos
Message 2 of 12
(6,060 Views)
Hi!

I've done all this, but it still doesn't work. I managed
to read/write to the power supply yesterday, but I'm
writing commands, like in Hyperterminal, to set the
voltage level etc.

Børild
0 Kudos
Message 3 of 12
(6,041 Views)
Hi!

I've done all this, but it still doesn't work. I managed
to read/write to the power supply yesterday, but I'm
writing commands, like in Hyperterminal, to set the
voltage level etc.

Børild
0 Kudos
Message 4 of 12
(6,040 Views)
Hi Børild,
 
Could you please elaborate on what you mean by it doesn't work?  Providing screenshots, error codes, error messages, your VI's and/or code would allow us to understand the problem and help you debug it.
 
Let us know.
 
Regards,
Berk
Instrument Drivers / IVI
0 Kudos
Message 5 of 12
(6,023 Views)

Hi,

When you mention

"but the commands won't work in LabView when I try communicating through a VISA-session"

are you seeing an error? can you please add more details along with the versions of the driver, LV, VISA, and ICP?

and possibly create a NI Spy Capture?

0 Kudos
Message 6 of 12
(6,022 Views)
I have the same problem. I can communicate with Power supply using Hiperterminal, but not LabView,
0 Kudos
Message 7 of 12
(5,515 Views)

I had the same problem, then I started to write my own vi and I can talk to the power supply. You van download from the attachment section.

 

Message Edited by paul lim on 02-10-2009 01:37 PM
Message Edited by paul lim on 02-10-2009 01:39 PM
Message Edited by paul lim on 02-10-2009 01:42 PM
0 Kudos
Message 9 of 12
(5,457 Views)

Can you put the VI? not a picture?

 

thank you

0 Kudos
Message 10 of 12
(5,448 Views)