09-26-2013 07:05 AM
I have installed LabVIEW 2013 for Linux on a Scintific Linux machine, version 6.4 . Both VISA and DAQmx Base (version 3.7) was also installed without any problems. But when I try to run lsdaq to recognise a NI device (USB-6009) I get this error message:
Detecting National Instruments DAQ Devices
Found the following DAQ Devices:
libnipalu.so failed to initialize
Perhaps you need to run updateNIDrivers
/usr/local/bin/lsdaq: line 7: 2367 Aborted /etc/natinst/nidaqmxbase/bin/daqmxbase_listdevices
I have tried updateNIDrivers, also running without any problems, and drivers were upgraded. But the same thing happens when I run lsdaq. What can I do to solve this?
Regards
Per Jørgensen
12-16-2013 07:47 AM
Hi Per,
Maybe the firmware is incompatible?
http://digital.ni.com/public.nsf/websearch/91CBCFE9E171C845862572CF0077D8F9?OpenDocument