Issue:
Dynamic Launching of a VI works fine when the plug-in code is launched from the LabVIEW source code.
When the Application was build it fails to launch the VI. Upon debugging I found that I am reusing some of the SubVIs in the plug-in VIs that is part of the EXE. I tried renaming and re-linking of those Vis for the Plug-in VIs it works fine.
Solution:
Similar to Name spacing provided by Lvlib files. Add an additional option in the Exe build spec, to add a name space for the application this will rename all the VIs as "my project:main.vi, My project:test1.VI" etc inside the Exe. This will resolve the naming issue created by the LabVIEW runtime engine. So a plug-in VI can reuse the test1.Vi from the Source code.